D26 Y026A (Qiu Long)

The cause of this fault with the speed control handle is often due to poor contact of the linear Hall element leads, resulting in intermittent output control voltage. To troubleshoot this issue, we only need to check if the Hall leads are loose, use a multimeter to check if the 5V power supply pin is functioning properly, and ensure that the magnet assembly and reset spring are in their normal positions. If repair is difficult, it is recommended to replace the speed control handle with a new one to resolve the issue.

Classification:

Electric friction switch series

Keywords: motorcycle switch series | rocker arm bearing series | rocker arm bearing series | electric motor switch series | handlebar accessories


Message

Product Description

The cause of this fault with the speed control handle is often due to poor contact of the linear Hall element leads, resulting in intermittent output control terminal voltage. To troubleshoot this issue, we only need to check if the Hall leads have any loose connections, use a multimeter to check if the 5V power supply pin is functioning normally, and ensure that the magnet assembly and reset spring are in their correct positions. If repair is difficult, it is recommended to replace the speed control handle with a new one to resolve the issue.